Strona 1 - Redundant Configuration

User GuideKu BandSolid State Amplifiers – SSPARedundant Configuration

Strona 2 - Equipment Supplied

UPCOM TECHNOLOGIES@BCL@1408FB8F 10Status Display (Optional )This indicator shows the general status of the Outdoor SSPA – if everything is good, or if

Strona 3 - General Information

UPCOM TECHNOLOGIES@BCL@1408FB8F 11Temperature CompensationTighter temperature compensation response is also possible with the attenuator mod

Strona 4 - Ports and Interfaces

UPCOM TECHNOLOGIES@BCL@1408FB8F 12Redundancy Interconnection DiagramBUCBUCSSPASSPAM&CRS485INDOORSwitchLoad6pin connectorSWOV10pin connectorSWOV10p

Strona 5

UPCOM TECHNOLOGIES@BCL@1408FB8F 13 Quick Start Guide Check the connectivity of the AC Pins and also at the AC Cable to make sure that Line or Neutra

Strona 6

UPCOM TECHNOLOGIES@BCL@1408FB8F 14General MaintenanceWith proper care and maintenance, your SSPA will provide many years of reliable serv

Strona 7 - Monitors and Controls

UPCOM TECHNOLOGIES@BCL@1408FB8F 15Theory of OperationAC / DC ConverterThe prime AC input power is delivered to a converter module that pro

Strona 8

UPCOM TECHNOLOGIES@BCL@1408FB8F 16 Appendix AOperating Frequency Range 13.75 - 14.5 GHz Output Power 1dB Comp 47 dBmInput Power @ P1dB ou

Strona 9 - @BCL@1408FB8F 9

UPCOM TECHNOLOGIES@BCL@1408FB8F 17Appendix B

Strona 10 - @BCL@1408FB8F 10

Outdoor Band Solid State Amplifier System – Redundant ConfigurationUser GuideThis section provides general information for the UPCOM TECHNOLOG

Strona 11 - Menu Items (Optional )

General InformationSafety ConsiderationsPotential safety hazards exist unless proper precautions are observed when working with this unit. To ensure

Strona 12

Ports and InterfacesPrime Power ConnectionThe Prime Power Connector is the point where the unit receives input power. A connector 3100

Strona 13 - Quick Start Guide

The maximum input level should be limited to +33 dBm to avoid damaging the unit.RF Output The RF Output is brought out through waveguide in the Outdoo

Strona 14 - General Maintenance

D Tx-AirflowThe air intake and exhaust are both located on the bottom side of the SSPA. The intake is brought through one or two fans

Strona 15 - Theory of Operation

Monitors and Controls Monitor signals and Control lines are present on the M & C Connector when this option is installed. Typical

Strona 17 - Appendix B

UPCOM TECHNOLOGIES@BCL@1408FB8F 9Temperature MonitorThe temperature of the unit baseplate is monitored by a voltage analogous to temperat